Preview

Orgo Post Lab

Powerful Essays
Open Document
Open Document
600 Words
Grammar
Grammar
Plagiarism
Plagiarism
Writing
Writing
Score
Score
Orgo Post Lab
Haylee McHale
February 3, 2013
Organic Chemistry Lab 226
Section 6
Techniques Lab 1. % Recovery= grams recovered compoundgrams crude compound X 100
% Recovery= 0.040 grams0.256 grams X 100
% Recovery= 0.16 x 100=16%
There are many reasons why the percent recovery is much less than 100%. For example, one source of error may have been that the separatory funnel containing the acidified phenylalanine and ethyl acetate may not have separated well enough after being shaken together in the funnel. Not allowing an adequate amount of time for the aqueous and organic layers to separate will cause portions of the layers to be contaminated. This would affect the experimental results because when the aqueous layer was drained into a separate beaker, some of the phenylalanine would also drain out too. This would result in a loss of recovered compound. One way that this was limited was by repeating the mixing and draining process two more times; however, one cannot entirely ensure that all of the compound has been removed. A second source of error may have occurred during the vacuum filtration step. After the flask containing the organic solution and drying reagent was poured into the Hirsch funnel, the “mother liquor” was collected in the flask below. This liquid contained the phenylalanine compound that would later be recovered. After this step, ethyl acetate was used to rinse out the original flask containing the solution to ensure that all of the phenylalanine has been retrieved along with the drying reagent. One error may have been that the original flask may not have been rinsed well enough and some of the phenylalanine remained in the original flask. This would affect the end results by lowering the percent recovery due to the left behind phenylalanine in the original flask.

2. Infrared Spectrum Position | Intensity | 409.27 | 90.044 | 467.13 | 76.245 | 522.73 | 62.180 | 603.52 | 82.948 | 680.90 | 74.047 | 697.68 | 63.592 | 744.46 |

You May Also Find These Documents Helpful

  • Satisfactory Essays

    Error in the yield could be due to the aforementioned volatility of the product, especially since the solution required multiple transfers exposing it to air and allowing evaporation whenever it was uncapped. Further error would be due to having accidentally left the cap off of the vial while washing the Hickman head with saturated sodium chloride allowing more evaporation than would be expected in this…

    • 894 Words
    • 4 Pages
    Satisfactory Essays
  • Better Essays

    orgo lab

    • 993 Words
    • 4 Pages

    The results of the experiment show a percent yield of 34.34% for the first trial (Part A), and a percent yield of 84.0% for the second trial (Part B). The methods for both trials were generally the same, so the large difference is attributed to the fact that the beaker broke before the gravity-filtering step in the first trial. The beaker was attempted to be picked up by the beaker tongs, but as the hot solution was being poured into the filter, the beaker slipped out of the beaker tongs and shattered, leaving some of the product unfiltered and thus not accounted for in the final product. Although the methods were generally similar in both steps, the gravity filtration step was skipped over in the second trial, which may have accounted for the missing 16% in trial 2, but may have also accounted for the overall relatively high percent yield for this trial. Luckily, the actual melting point of benzoic acid fit within the recorded average…

    • 993 Words
    • 4 Pages
    Better Essays
  • Better Essays

    Organ lab1

    • 1822 Words
    • 5 Pages

    A distillation experiment was performed in attempt to separate two miscible fluids.This experiment used fractional distillation to separate ethanol from the azeotropic mixture of ethanol and water. The initial composition of the solution did not matter because the goal of the experiment was to distill the ethanol-water solution and obtain 95% ethanol in the distilled fraction. The percentage composition is obtained by the calculated density of distilled product. The azeotropicmixture was separated using a fractional distillation apparatus. The apparatus contained a fractional distillation column with acopper sponge; this was used to capture the water vapor to repeat the simple distillation process, this method yield 88% of ethanol. This form of distillation was shown to be effective in distilling a mixture with similar boiling points.…

    • 1822 Words
    • 5 Pages
    Better Essays
  • Satisfactory Essays

    Orgo Lab 5

    • 539 Words
    • 3 Pages

    The objective of this experiment was to carry out an elimination reaction on 2-methylalcohol with an acid to produce alkenes as a product. The product formed is separated through distillation. Because more than one alkene product can result from the reaction, Gas Chromatography is used to analyze the composition of the product mixture. IR spectrometry is also carried out to confirm the product.…

    • 539 Words
    • 3 Pages
    Satisfactory Essays
  • Satisfactory Essays

    Lab Report 2

    • 604 Words
    • 3 Pages

    1. If the room temperature for this experiment had been lower, the length of the resonating air column would have been shorter. The length of air column is directly proportional to temperature due to v=331msT273 .…

    • 604 Words
    • 3 Pages
    Satisfactory Essays
  • Better Essays

    Formal Lab 3

    • 1114 Words
    • 12 Pages

    enantiomer of the molecule Naproxen is used to treat arthritis pain but the other enantiomer…

    • 1114 Words
    • 12 Pages
    Better Essays
  • Good Essays

    post lab 6

    • 593 Words
    • 2 Pages

    2 - Cool the solution to room temperature and add ~ 0.5 to 1 ml of bromocresol green indicator,solution turns into blue. Titrate it with HCl until green color is reached. (DO NOT OVER TITRATE)…

    • 593 Words
    • 2 Pages
    Good Essays
  • Satisfactory Essays

    PRE LAB

    • 445 Words
    • 4 Pages

    Which type of compound usually has higher melting points: ionic compounds or covalent compounds? What is the reason for this difference in melting points? (3 points) Ionic compounds have higher melting and boiling points than covalent compounds. The electrostatic attraction in an ionic bond is very strong hence a lot of heat energy is required to break it down, ionic bonds have high melting and boiling points. In covalent bonds, the intermolecular forces are very weak and are easily broken, hence lesser heat is required and thus covalent bonds have lower melting and boiling points.…

    • 445 Words
    • 4 Pages
    Satisfactory Essays
  • Good Essays

    Pglo Lab Report

    • 548 Words
    • 3 Pages

    The pGLO lab is a lab where students attempt to put the genes that make a jelly fish glow into E. Coli. After a process called transformation, the process in which a cell takes up and expresses a new piece of genetic information, the E. Coli will be able to glow and will be antibiotic resistant. The students first need to learn a couple of techniques before they are able to begin this lab. The first technique they will need is how to keep their environment sterile. They must learn to only open their tools, and other supplies for as long as they need, and keep them from touching anything. They must also learn that tools can never be shared between specimens, and when they use a tool, they should dispose of it and get a new one. Next they need to learn how to transfer a bacterial colony. To do this, one must use a sterile loop and scrape one colony off of the dish. Then they must insert the loop into…

    • 548 Words
    • 3 Pages
    Good Essays
  • Good Essays

    Limiting Reactant Lab

    • 1092 Words
    • 5 Pages

    A piece of filter paper was placed on the funnel and moistened with distilled water. With the aspirator on, the contents of flask 1 was poured into the funnel. The flask was rinsed out with distilled water and poured into the funnel in order to get most of the salts out of the funnel. The aspirator sucked the filtrate through the filter funnel. Once most of the liquid has been removed from the filter funnel, but the solid was still wet, 10 Ml of ethanol was added to the solid in the filter funnel. The ethanol was sucked through the filter funnel. The aspirator continuously ran in order to dry the solid on the filter funnel. Five vials were obtained and labeled with name, reaction number, and the flask number. The empty vials were weighed and their mass was recorded. When the solid was dry enough to remove from the filter funnel, the aspirator was turned off and the filter paper was removed from the suction flask. A spatula was used to gently remove the solid from the filter paper and placed into the corresponding vial. This process was repeated for all five Erlenmeyer flasks. Once completed, the vials with the solid contents were massed. After a week of drying, the vials were obtained and massed again. A graph using Excel was…

    • 1092 Words
    • 5 Pages
    Good Essays
  • Good Essays

    Lab Report

    • 366 Words
    • 2 Pages

    First, I would take a sample from different areas of the water to test the amount of dissolved oxygen in the water. Then after completing this test, I would check to see if there is” of course “an increase in the fish present in the water. This observation would help keep track of the fish present in different areas of the water and furthermore, I would be able to compare results.…

    • 366 Words
    • 2 Pages
    Good Essays
  • Good Essays

    pre lab

    • 405 Words
    • 2 Pages

    The purpose of this experiment is to become familiar with the precision and accuracy of scientific glassware.…

    • 405 Words
    • 2 Pages
    Good Essays
  • Good Essays

    1.08 Percent Yield

    • 444 Words
    • 2 Pages

    The percent yield was calculated to be 85% indicating a source of error. The low percent yield means that some product was lost. We most likely did not wash the flask enough since there was some amount of white substance on the sides of the flask. A lot of precipitate also did not form, so most of the product could have been filtered into the filtrate. We could have had a higher percent yield if we would have washed the sides of the flask more.…

    • 444 Words
    • 2 Pages
    Good Essays
  • Good Essays

    Objective: The objective of this lab was to find the concentration of an unknown alcohol solution.…

    • 918 Words
    • 4 Pages
    Good Essays
  • Good Essays

    Oopp Lab Work

    • 1489 Words
    • 6 Pages

    CSE219 OBJECT – ORIENTED PROGRAMMING LAB Cycle Sheet – I 1. Create a class that registers your details by taking reg.no, name, age and mail id. Create a function that prevents duplicate entries of objects based on reg.no. (b) 2. Create a class account that maintains acc_no, name, and balance. Perform deposit, withdrawal and statement print operations. (statement print must print all the transactions that has taken place so for – use structures inside the class to maintain the details about transactions)(b) -----------------------------------------------------------------------------------------------------3. Create a class that holds the details of the mobile phone like brand, imei, no of sim cards, phone numbers etc.,. Allow user to login with their mobile no. Use a function that sends a message from that mobile. Maintain the details of the message as a static member inside the send message function and display each time all the messages sent from that mobile. (b) 4. Create a class ID_card that maintains the details in an ID card. Perform insert, update, delete and display operation through functions that takes input through reference parameter. (c) ----------------------------------------------------------------------------------------------------5. Create a C++ program that takes employee details like ID, first name, last name, age and address. Create a class for student {name, course, regular/parttime, address}. Use friend function to check that a student with same name and address can’t be a regular student as well as an employee. (c) 6. Synthesize a C++ program that has two classes (one for employee and one for student), have a separate class for address (with door no, street name, city, state) and reuse address both for employee and student. Perform insert, delete and display operations by taking choice of person (employee or student) from the user. Allow user to have more than one address also. (c)…

    • 1489 Words
    • 6 Pages
    Good Essays